Environmental Testing IEC 60068-01-78 : 2012 Damp Heat, Steady State

Evaluating a product’s endurance against prolonged moisture exposure is critical for global market access. IEC 60068-2-78 provides a rigorous framework to assess how non-dissipating and heat-dissipating equipment handles high-humidity environments without the stress of temperature fluctuations. This testing ensures long-term reliability by identifying:

  • Insulation Degradation: Detecting electrical leakage and dielectric breakdowns.
  • Material Integrity: Evaluating swelling, warping, or chemical changes in plastics and coatings.
  • Corrosion Kinetics: Identifying oxidation risks in connectors and PCB traces.

Talk to a Specialist

Share your details and we will reach out within one business day.

By submitting, you agree to our privacy policy and consent to be contacted.

Benchmark: International Compliance Standards

The primary reference is IEC 60068-2-78:2012 (and the updated 2025 version). In the Indian context, this aligns with IS 9000 (Part 4). These standards define the "Test Cab" methodology, maintaining a constant temperature (e.g., $40^{\circ}\text{C}$ or $85^{\circ}\text{C}$) and relative humidity (85% to 93%) to simulate tropical or industrial environments.

Targeted Infrastructure: Products Under Evaluation

This testing is mandatory for a wide array of high-stakes hardware, including:

  • Consumer Electronics: Mobile devices, laptops, and home appliances.
  • Telecommunications: 5G Infrastructure, routers, and outdoor network nodes.
  • Automotive Components: Sensors, ECUs, and infotainment systems.
  • Industrial Automation: PLCs, control panels, and power supplies.

Technical Breadth: Scope of Environmental Testing

The scope extends beyond mere "moisture resistance." It involves a comprehensive assessment of the specimen's physical and functional stability. Testing parameters include:

  • Severity Levels: Standardized durations ranging from 4, 10, 21, to 56 days.
  • Functional Monitoring: Real-time performance checks while under environmental stress.
  • Visual Inspection: Microscopic analysis for cracks, delamination, or discoloration post-test.

Certification Credibility: Lab Accreditation Requirements

To be valid for BIS, TEC, or international CDSCO/ISO filings, testing must be performed in a laboratory accredited by NABL (National Accreditation Board for Testing and Calibration Laboratories) or an ILAC-MRA signatory. This ensures the precision of the environmental chambers and the traceability of the results.

Project Lifecycle: Expected Testing Timelines

The timeline is largely governed by the "Severity" level chosen:

  • Standard Testing: Typically 10 to 21 days.
  • Critical Infrastructure: May extend to 56 days for long-term durability claims.
  • Reporting: An additional 3–5 business days post-testing for the final NABL-accredited report.

Logistics & Submission: Sample Requirements

  • Quantity: Generally 1 to 2 units (one for testing, one as a golden sample/backup).
  • Condition: Samples must be in their final production form with all enclosures and seals intact.
  • Accessories: All necessary power cables and software required for functional operation during the test must be provided.

Investment Strategy: Testing & Certification Costs

The cost is variable based on the following factors:

  • Test Duration: Longer "Severities" (e.g., 56 days) incur higher chamber utility fees.
  • Functional Testing: Requirements for continuous monitoring by lab engineers.
  • Lab Status: Private NABL labs vs. government-aided labs (like ERTL/ETDC).
  • Estimates typically range from ₹15,000 to ₹60,000+ depending on complexity.

Compliance Dossier: Documentation Checklist

To initiate the process, the following data is essential:

  • Technical Specifications: Data sheets covering operating temperature and humidity limits.
  • Circuit Diagrams: For identifying critical moisture-sensitive components.
  • User Manual: To guide the lab on "Standard Operating Conditions" during functional checks.
  • BOM (Bill of Materials): Highlighting the ingress protection (IP) ratings of the external housing.

Frequently Asked Questions

IEC 60068-2-78 maintains constant, steady-state humidity levels, whereas IEC 60068-2-30 involves cyclic temperature changes that purposefully induce condensation on the test specimen for stress analysis.

Talk to a Specialist

Share your details and we will reach out within one business day.

By submitting, you agree to our privacy policy and consent to be contacted.

Why Choose Instacertify

Trusted, specialized, and efficient compliance support.

Comprehensive

Compliance Solutions

🎯

Expertise in

Certification Services

🤝

Reliable

Compliance Consulting

Efficient

Certification Advisory

What Our Customers Say

Trusted by thousands of happy customers.

Newsletter Background

Stay Informed

Get Compliance Updates & Expert Insights

By subscribing, you agree to our Privacy Policy and consent to receive updates from our team.